InfraredHeaters.com Questions? 1-800-442-2581 |
Our secure online
ordering website: www.MorElectricHeating.com.
|
|
Home | Products | Accessories | Ordering | Contact Us | Search | ||
SWB Radiant Fixture Installation and Maintenance Instructions
SWB installation instructions in .pdf format | You must have the free Adobe Acrobat Reader plug-in. |
Warning
THIS INSTRUCTION SHEET CONTAINS IMPORTANT INFORMATION FOR THE PROPER INSTALLATION, USE, AND EFFICIENT OPERATION OF THE SWB RADIANT FIXTURE. CAREFULLY READ THIS SHEET BEFORE INSTALLING AND OPERATING THIS FIXTURE. FAILURE TO ADHERE TO THESE INSTRUCTIONS COULD RESULT IN FIRE, ELECTRICAL SHOCK, DEATH, SEVERE BURNS, OR PROPERTY DAMAGE.
Hazard of fire: THIS INSTRUCTION SHEET CONTAINS IMPORTANT INFORMATION FOR THE PROPER INSTALLATION, USE, AND EFFICIENT OPERATION OF THE SWB RADIANT FIXTURE. CAREFULLY READ THIS SHEET BEFORE INSTALLING AND OPERATING THIS FIXTURE. FAILURE TO ADHERE TO THESE INSTRUCTIONS COULD RESULT IN FIRE, ELECTRICAL SHOCK, DEATH, SEVERE BURNS, OR PROPERTY DAMAGE.
Hazard of fire:
* Do not mount SWB fixture near combustible materials or within a hazardous area.
* Do not recess the SWB fixture into a wall. The fixture must be surface mounted using the
included mounting brackets or hung by chain.
* Keep drapery, clothes, rags, and other combustible items away from the fixture.
* Use high temperature wire for electrical connections within fixture/terminal area.
Electrical Shock:
* Disconnect electrical power before servicing emitters. All electrical wiring must be
done in accordance to local electrical codes by a qualified service technician.
* Do not touch the ceramic emitters after power is applied to the emitters.
* Never immerse ceramic emitters in liquids.
Severe Burns:
* Ceramic emitters operate at high temperatures. Do not touch emitters or housing after
power is applied.
Wiring
High temperature wire, with insulation suitable for the load amperage and operating temperatures, must be used to make the power connections to the ceramic terminal blocks.
All electrical wiring must be done in accordance with local electrical codes by a qualified service technician.Reflector Assembly and Parts Identification
1). Mounting Bracket Assembly and Hardware
2). Rubber Grommet
3). Aluminized Steel End Cap
4). Terminal Cover Housing
5). Ceramic Bushing
6). TB-3, 3 Pole Ceramic Terminal Block
7). TB-2, 2 Pole Ceramic Terminal Block
8). Reflector Assembly
9). Pilot Light
10). Ceramic Emitter with Mounting Clip
To order replacement parts contact us
We are a distributor of infrared heaters. Always consult manufacturers installation instructions for proper installation of the products or systems shown on this website. © Copyright 1999-2019 Mor Electric Heating Assoc., Inc. MOR
ELECTRIC HEATING ASSOC., INC. |