Calorique Radiant Floor Heaters


We are an authorized distributor for
Calorique, Ltd.

 |
 |
|
Calorique Floor Warming |
Calorique's floor warming system provides even,
comfortable warmth that permeates a room. With floor warming, not
only are surfaces warmed and people made comfortable, but the floor
is warmed to just the right amount for it to be the most pleasant to
walk upon.
| |
 |
|
Conventional Heating System |
Because radiant heat does not depend upon moving
large volumes of air, dust and contaminants in the air and room are
reduced.
Calorique's radiant floor warming systems are
extremely energy efficient. Homeowners throughout the world use
floor warming systems not only for their increased comfort levels,
but also because they use as much as 20% less energy than other
forms of heating, since all the heat energy is directed into the
living space rather than heating the air along the walls.
Warm Floors Under-Floor
Warming System
 |
 |
|
Installed Warming Elements |
Ideal for new construction and areas where access
to the floor joists is possible, the Under-Floor Warming System is
attached between the floor joists with a small, 2" (5 cm) air space
between the elements and the floor surface.
All panels are 12
5/8" long, all
rolls are on 3' cores, nominal heating
panel thickness a 19mils


| |
Frequently Asked Questions
 |
 |
| How much
power does the system use? |
 |
| |
12" on center: |
6 watts per panel (roughly 12.5" long) |
| |
16" on center: |
10 watts per panel |
| |
24" on center: |
15 watts per panel |
 |
 |
| How much
does it cost to operate? |
 |
| |
A typical 8' by 10' bathroom will cost
about 2 cents per day.
(Assuming 10 cents per kilowatt hour electric cost. Your
costs may vary.) |
 |
 |
| What
kind of floor covering can I use? |
 |
| |
Any standard floor covering including
hardwood, tile, linoleum, brick, etc. Consult the
installation manual for specific thicknesses and
combinations. |
| Why does
it have the air gap? |
 |
| |
This spreads the heat out, making it
more even, and also allows the heat to enter the room from
under a couch without being trapped, which is inefficient. |
 |
 |
| Can I
install the elements directly under tile? |
 |
| |
No. |
 |
 |
| Do I
have to leave access below the elements? |
 |
| |
No. |
 |
 |
| Do I
have to wire both ends of the elements? |
 |
| |
No. |
 |
 |
| Why
would I want to wire from both ends? |
 |
| |
This protects the operation of the
elements. If, for example, a bus bar were severed during
renovation work*, the entire element would continue to
operate.**
* Always turn off power to the elements when doing
renovation work to the floor or the ceiling below it.
** If a bus bar is severed, make sure that the severed
ends are properly insulated before restoring power to the
system. |
 |
 |
| How many
amps does the system use? |
 |
| |
The typical 8' by 10' bathroom uses
less than 2 amps at 120 volts. |
|
|
• All panels are 12 5/8” long, all rolls
are on 3” cores, nominal heating panel thickness is 9mils

Crimp Connector to make permanent electrical connection from lead wires to
heating panel bus-bars and Plastic Insulator to
enclose connection to heating panel

Crimping Tool specifically designed to crimp the connector to the heating panel
bus-bars

Electrical Wire (BLACK) - Type UF 12 ga single conductor wire for connecting
heating panels

Electrical Wire (WHITE)
- Type UF 12 ga single conductor wire for connecting heating panels
|
Secure Online Ordering
Delivery time for the following products: Typically
shipped in 5-7 working days
or less. The transit time to you depends on your
physical location and your selected UPS/FedEx
shipping method, the cost of which will be displayed in your shopping cart. |
| Item
ID |
Catalog # |
Volts |
Description |
Quantity |
Price |
Click "Select" Below |
|
Sold by the panel: |
|
CALOR10015 |
FLR13P8W120V-Panel |
120 Volts |
Under Floor Heating Elements designed for
installation between floor joists with 12"
centers, 8w/panel |
1-249 panels |
$4.09 |
 |
| CALOR10027 |
FLR13P8W240V-Panel |
240 Volts |
Under Floor Heating Elements designed for
installation between floor joists with 12"
centers, 8w/panel |
1-249 panels |
$4.09 |
 |
| CALOR10001 |
FLR17P11W120V-Panel |
120 Volts |
Under Floor Heating Elements designed for
installation between floor joists with 16"
centers. 11w/panel |
1-249 panels |
$5.48 |
 |
| CALOR10028 |
FLR17P11W240V-Panel |
240 Volts |
Under Floor Heating Elements designed for
installation between floor joists with 16"
centers. 11w/panel |
1-249 panels |
$5.48 |
 |
| CALOR10021 |
FLR25P17W120V-Panel |
120 Volts |
Under Floor Heating
Elements designed for installation between floor
joists with 24" centers, 17w/panel |
1-249 panels |
$6.83 |
 |
| CALOR10032 |
FLR25P17W240V-Panel |
240 Volts |
Under Floor Heating
Elements designed for installation between floor
joists with 24" centers, 17w/panel |
1-249 panels |
$6.83 |
 |
|
Sold by the roll of 250 panels: |
| CALOR10033 |
FLR13P8W120V-Roll |
120 Volts |
Under Floor Heating Elements designed for
installation between floor joists with 12"
centers, 8w/panel |
250 panels (2.0kW) |
$886.67 |
 |
| CALOR10030 |
FLR13P8W240V-Roll |
240 Volts |
Under Floor Heating Elements designed for
installation between floor joists with 12"
centers, 8w/panel |
250 panels (2.0kW) |
$886.67 |
 |
| CALOR10029 |
FLR17P11W120V-Roll |
120 Volts |
Under Floor Heating Elements designed for
installation between floor joists with 16"
centers. 11w/panel |
250 panels
(2.75kW) |
$1,186.67 |
 |
| CALOR10026 |
FLR17P11W240V-Roll |
240 Volts |
Under Floor Heating Elements designed for
installation between floor joists with 16"
centers. 11w/panel |
250 panels
(2.75kW) |
$1,186.67 |
 |
| CALOR10034 |
FLR25P17W120V-Roll |
120 Volts |
Under Floor Heating
Elements designed for installation between floor
joists with 24" centers, 17w/panel |
250 panels
(4.25kW) |
$1,480.00 |
 |
| CALOR10035 |
FLR25P17W240V-Roll |
240 Volts |
Under Floor Heating
Elements designed for installation between floor
joists with 24" centers, 17w/panel |
250 panels
(4.25kW) |
$1,480.00 |
 |
|
Accessories: |
| CALOR10003 |
FC-1001 |
120 or 240 Volts |
Crimp connector to make
permanent electrical connection from lead wires to heating panel bus bars. |
1 |
$0.69 |
 |
|
CALOR10002 |
FB-1001 |
120 or 240 Volts |
Plastics insulator to enclose connection to heating panel |
1 |
$0.69 |
 |
| CALOR10004 |
FCT-104 |
120 or 240 Volts |
Crimping tool
specifically designed to crimp the connector to the heating panel bus bar. |
1 |
$64.62 |
 |
| CALOR10009 |
UF-1-12R |
120 or 240 Volts |
Electrical Wire (Red) - Type
UF, 12 gauge single conductor for connecting heating panels |
Sold by the foot |
$0.43 |
 |
| CALOR10006 |
UF-1-12B |
120 or 240 Volts |
Electrical Wire (Black) - Type
UF, 12 gauge single conductor for connecting heating panels |
Sold by the foot |
$0.43 |
 |
| CALOR10007 |
UF-1-12W |
120 or 240 Volts |
Electrical Wire (WHITE)
- Type UF 12 ga single conductor wire for connecting heating panels
|
Sold by the foot |
$0.43 |
 |
|